Aranet4 is an innovative battery-powered stand-alone wireless sensor for monitoring CO2, temperature, relative humidity and atmospheric pressure at home, school, office or another indoor environment. The device is portable, simple to install, easy to operate and lets you know when the monitored levels have become unhealthy.
Aranet4 PRO sensor
Aranet4 PRO sensor Measurements CO2 (carbon dioxide), temperature, relative humidity, atmospheric pressure Line of Sight Range Bluetooth up to 10 m / 33 ft
Aranet radio up to 3 km / 1.9 miOperating environment Indoor use Transmitter power Bluetooth: -12 dBm or 4 dBm
(selectable by user)
Aranet LoRa radio: 14 dBmFrequency Depends on base station instructions Measurement range CO2 0-9999 ppm
temperature 0 °C to 50 °C (32 °F to 122 °F)
relative humidity 0 % to 85 % RH
atmospheric pressure 0.3 to 1.1 atm (4.4 to 16.0 psi)Measurement accuracy* CO2 0-2000 ppm: ±50 ppm or 3% of reading 2001-9999 ppm: ±10% of reading
temperature ±0.4 °C (0.72 °F)
relative humidity ±3%
atmospheric pressure ±0.001 atmSensor Uses the nondispersive infrared (NDIR) sensor to measure CO2 CO2 measure calibration Automatic or manual (at 420 ppm) Data Transmission 1, 2, 5, 10 minutes Data Protection Data encryption Power options 2 AA Alkaline batteries Battery life Up to 2 years** Operating temperature 0 °C to 50 °C (32 °F to 122 °F) Operating humidity 0% to 85% non-condensing Dimensions 70 x 70 x 24 mm/2.76″ x 2.76″ x 0.94″ Weight 104 g (3.7 oz) Construction Polycarbonate Protection class IP20 Marking CE Compatible base stations Aranet PRO (from v1.3.2) Included 2 AA Alkaline batteries Part number TDSPC003 (EU)
TDSPC0U3 (NA)
TDSPC0R3 (RU)* For best accuracy, recommended operating range is 10°C to 40°C (50°F to 104°F) and 20% to 60% RH (non-condensing).
Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
** Bluetooth pairing disabled, LoRa radio disabled, data transmission at a 10 minute interval.Aranet4 is not impact resistant!
Do not use the device in high humidity environments (greater than 85%)!
Do not leave the device in direct sunlight!